2007 - Oil products distribution terminals

One of the conclusions from the inquiry into the Buncefield oil storage depot explosions and fire was that organisations must have effective shift handover arrangements.

Andy was asked to review arrangements at two of the client's sites to determine if they were suitable and sufficient. He was provided with copies of logs, handover procedures and audit findings; and had informal discussions with personnel. Comparing with available guidance he concluded that the existing system were too informal and ad hoc, and so needed improving. However, he recognised that no problems were identified with the way handovers were actually carried out in practice, and so was able to recommend that the action required was to largely formalise existing arrangements rather than generate a new system.